给我们打电话!

The road to comfort in 育空,好  is 州际加热 & beplay2网址. The road to comfort in 育空,好 is 州际加热 & 空气

调节. 阅读我们的育空, OK reviews to see why we are the trusted route for reliable heating and air conditioning services.

Most home air conditioner repairs are minor and cost around $300 in the 育空河 OK area. The price depends mainly on what is wrong with the AC, and can range from as little as $100 all the way up to over $2,000用于主要修复.

你知道州际供热公司吗 & beplay2网址 offers a 100% satisfaction guarantee on all of our 维修服务? 今天就与我们联系 要了解更多!

平均, 你可能要付7美元,000 – $12,500 for a new heating and cooling system in the 育空河 OK area. 这个价格包括安装和管道系统, as experts estimate around 80% of HVAC replacements also need ductwork replacement as well. 最终的成本还取决于:

  • The size of the home that is being heated and cooled.
  • The quality and energy efficiency rating of the new unit.
  • If there is a complex ductwork network to be replaced.

To learn more about the cost of heating and air units, 今天电话beplay靠谱嘛! 我们提供免费的估价 新单元的安装 以及100%的满意保证.

Some tips to help keep your air conditioner from freezing up include:

  • 准时更换空气过滤器. When the airflow to a unit is blocked by a dirty air filter, the coil will develop an ice layer.
  • Make sure the condensate drain line is not obstructed. 湿气积聚会导致机组结冰.
  • 保持通风口开放. Make sure that all the home’s vents and return registers are open and clear of obstructions.

If your unit keeps freezing up, 州际加热 & beplay2网址可以帮上忙. 我们提供专业提示 beplay2网址维修服务 以可承受的利率. 现在beplay靠谱嘛!

当地的评论
育空,好

州际加热 & beplay2网址 额定 4.9 满分5分 基于 44 顾客评论


很好的服务




州际供热回顾 & beplay2网址

快速、高效的服务.


很好的服务




州际供热回顾 & beplay2网址

Jason was professional, efficient and did a top notch job.


周末的礼拜很棒!




州际供热回顾 & beplay2网址


很好的服务




州际供热回顾 & beplay2网址

优秀的服务和专业的员工


很好




州际供热回顾 & beplay2网址

克里斯是优秀的! 迅速而有礼貌. 非常专业.


很好的服务 and very quick, professional and very courteous.




州际供热回顾 & beplay2网址

So very courteous and professional I’m considering have them install a new unit. 非常好的年轻人.


州际是伟大的.




州际供热回顾 & beplay2网址

州际棒极了, 他们会按时出现, 连你我的单位也老了, they still look at it to make sure it runs great. 我唯一的抱怨是办公室试图重新安排我第二次(第一次是因为有人生病了, 第二次,他们需要人力在不同的地点,没有beplay2网址),而我理解这是糟糕的没有beplay2网址,它已经变得热了,我真的不想走得更久,没有它被看, 因为我的部队太老了.


快速服务




州际供热回顾 & beplay2网址

Called at 2am and they got someone out the very next day! I have young children so the turn around time is very important to me. Repair man was friendly and kind, found out the issue quick and took care of it fast! 谢谢你!


很好的服务




州际供热回顾 & beplay2网址

提示、有礼貌、高效


交流访问压力




州际供热回顾 & beplay2网址

Chris was very professional, polite and thorough. 伟大的服务,任何访问州际公路. 强烈推荐!!


非常有益的




州际供热回顾 & beplay2网址


非常友好和伟大的服务




州际供热回顾 & beplay2网址

I had great service in Moore and continued using them when I moved to Mustang. Every person working at Interstate has been friendly and professional.


很好的服务




州际供热回顾 & beplay2网址

Great customer service, extremely friendly and very helpful and knowledgeable. 我一定会推荐这家公司吗.


艾萨克总是我的荣幸




州际供热回顾 & beplay2网址

艾萨克今天去看我的炉子了, 他总是做得很好, he’s been out to not only my house but my mothers as well, 州际间的高温和空气是最好的, 总是善良的.


很好的服务




州际供热回顾 & beplay2网址

热爱州际高温和空气


很好的服务




州际供热回顾 & beplay2网址

As always, great costumer service,very friendly and knowledgeable.


布兰登是伟大的!




州际供热回顾 & beplay2网址

伟大的工作!!! 准时和友好!


快捷友好的服务




州际供热回顾 & beplay2网址

This was the second time I’ve called on Interstate for service and they have been great to deal with. 从最初的电话与办公室和非常好的客户服务到预约的及时性和服务技术态度, 很高兴见到你.


暖通beplay2网址周日发布




州际供热回顾 & beplay2网址

周日的快速服务,艾萨克做得好. 因为他们一个月前才出来,所以免除了诊诊费,而且可能当时就应该添加制冷剂了. 会继续利用你们吗. 再次感谢


Suevey




州际供热回顾 & beplay2网址


Awesome service, great recommendation by the technician which saved me money and future issues.




州际供热回顾 & beplay2网址


服务




州际供热回顾 & beplay2网址

很好的服务


很好的服务




州际供热回顾 & beplay2网址

We had a great experience with 州际加热 & 空气! They were so quick to get someone out to our house and the work was done very fast too. The technician that did the work was kind, considerate and made sure to clean up after he was done. We had an all around amazing experience and would definitely recommend!


超棒的价格和伟大的价格!




州际供热回顾 & beplay2网址

亚当真的很好. 他非常专业. Very knowledgeable and patiently explained everything to us. Gave us recommendations on how to troubleshoot any future problems. Gave recommendations on other services to get the most out of our a/c unit. 服务的价格很好. 价格 is huge and he really eased any concern about it!! 从现在开始会使用它们吗.


很好的服务




州际供热回顾 & beplay2网址

及时、高效、有礼貌


杰森B.

杰森B.

07DEC2021 杰森B Arrived for no club tune up, code update, and real-estate inspection. Spoke with 首页owner about systems performance and scope of work. He requested we have the city out to inspect the system after code updates were made. As this system has already passed the city inspection we will not be able have them out again. I will guarantee all work done for one year, regardless of home occupants. 代码违反 -滴气腿不合适. 气滴腿或清洗必须配置在一种方式,强迫非可燃的滴水腿,以防止任何堵塞或损坏歧管. - Drain ran in front on furnace doors and interrupting 24” clearance required for work space. 24” are required Infront of furnace for work space, and clearance for 风机组装 removal. - Thermostat wire penetrates furnace without any protection from sharp edges. 任何进入熔炉的高或低压电线必须有romex连接或其他类型的保护,以防止损坏

附近 西南15露台, 育空河, OK 73099
rodneys@www.imperialcheats.com

rodneys@www.imperialcheats.com

10-12-2021- no heat, found inducer 电动机 bad, needs replaced. 10-13-2021- returned and replaced inducer fan 电动机, 检验操作, 诱导电机运行正常, 检查热交换器有无裂纹, 没有发现, 清洗和检查火焰传感器, 热表面点火器检查正常, 所有限制和安全检查正常, 调整歧管压力至 .5在厕所, 现在在MFG规格内, 更换了弱风机电机运行电容, 带tstat的循环系统, Tstat和系统运行正常. 进行一氧化碳test–0 ppm. 在蓝盾协议中登记了房主.

附近 阿伯丁博士, 育空河, OK 73099
杰森B.

杰森B.

杰森·B来到这里进行秋季调整. 我和玛西谈过系统性能. Cycle system on at thermostat then disconnect power at furnace. Pull blower and coil door, inspect heat exchanger, capacitor and blower 电动机. 重新安装鼓风机拉并清洁火焰传感器. 测试压力开关,然后重新接通电源. 循环系统在加热. 调整气体压力至3.5 IWC. 检查HSI,燃烧器和所有安全装置. Check amp draws, inducer, gas manifold, temperature split, and CO Levels. 此时系统运行正常. Please give us a call if there’s anything else we can help you with.

附近 Glascow博士, 育空河, OK 73099
艾萨克·J.

艾萨克·J.

Performed preventative maintenance on furnaces for customer. 检查过滤器, 风机组件, 电容器, 汽车, 电子元件蒸发器线圈, heat exchangers and overall condition of equipment. Cleaned 火焰传感器 and brushed dust off the 燃烧器. Checked thermostat operation, wiring, amps, temperatures and gas pressures of both furnaces. I will need to return to replace a UV bulb on north unit. Both systems are heating properly within manufacture specifications.

附近 温博士, 育空河, OK 73099
Kianoosh米.

Kianoosh米.

Duct cleaning inspection for home recently purchased. 首页owner looking to have ductwork cleaned today. Inspected ductwork in attic and inside supplies and returns. The system is undersized by 400 cfm if return air. This may lead to hot and cold spots in home during heating and cooling periods, as well as extra energy usage and possible premature breakdowns. 建议添加额外的14”回报, attaching a 2 foot return plenum and a 14x24” filter grill. The system also has a remote plenum box on east side of home that is servicing north east corner ductwork, 哪一段距离设备最远. Everything is good to complete a level 1 cleaning on. Also inspected dryer exhaust vent and it has been recently cleaned. 在需要的地方铺设床单. Removed supply vents, return grills and recently placed filters. Cleaned supplies with brush, and cleaning wipes / water from residual nicotine on them. 管道清洁用品,每个2-3个通道. 管道清洁返回3-4

附近 西北34圣, 育空河, OK 73099
约瑟夫·K.

约瑟夫·K.

我来到了一个红人的秋天调调. I inspect the system and found it to be a 23 year old system with a stopped up evaporator coil. The coil has a transition plate that is s and drive and it’s instant over the evening coil box. 我让房主意识到这一点,并建议清洁线圈,但让它清洁将是一个广泛的任务,线圈会破坏系统,因为它是老的,条件it’s. We decided to look at option repacking the furnace, furnace and evaporator coil or completely system. We decided to go with the complete system replacement. They will be contacting their bank for financing options so they can keep their discounts with us. We will preforming the free duct cleaning for them that is also including in their red club plan. We will try and make this duck cleaning on the same day as the system replacement. We also decided to purchase a 10 year labor warranty and keep the red club maintenance plan active. 我会继续跟进h

附近 SW第三平台, 育空河, OK 73099
克里斯·D.

克里斯·D.

到12月3日的炉调整检查流感换热器不能看到所有流感的方法结束时检查气体压力高、低阶段去除清洗和重新安装火焰传感器检查鼓风机客户更改自己的过滤器检查热表面点火器Everythinga€™s内制造规范

附近 克斯特大街, 育空河, OK 73099
克里斯·D.

克里斯·D.

Arrived on 3 December for furnace tuneup temperature is a little high due to a little dirt on the evaporator customer does not wanna clean it this time and the temperature rise is at 60 manufacture specifications stays between 35 and 65 but will provide customer with an estimate for cleaning evaporator this is a 20 year old furnace checked heat exchange removed cleaned and reinstalled 火焰传感器 checked flue change filters in the home show top surface 点火器 induced draft 电动机 everything is within tolerance on this unit.

附近 Bonnycastle Ln, 育空河, OK 73099
rodneys@www.imperialcheats.com

rodneys@www.imperialcheats.com

非俱乐部秋季服务. 首页owner maintains filters, blower 电动机 run capacitor was weak, rated at 7.5超滤,实际5.4uf, with homeowners permission I replaced blower 电动机 run capacitor, 清洗和检查火焰传感器, 压力开关检查良好, 滚出开关检查无误, 高限位开关检查正常, 调整歧管压力从4.从0到3.5在厕所, 现在在MFG规格内, 带tstat的循环系统, Tstat和系统运行正常. 一氧化碳测试- 0 ppm. 卖给房主一个管道清洁. 7供应1返回和$34/运行. Did explain to homeowner that when tech arrives he will check duct and may make further recommendations.

附近 西南15露台, 育空河, OK 73099
克里斯·D.

克里斯·D.

Arrived on 29 November for a furnace tuneup on inspection of the unit found that the blower 电动机 was dirty customer authorized cleaning in place cleaned the 火焰传感器 to gas pressures temperatures rise it is a 90% furnace inspected primary and secondary heat exchanger’s everything’s within manufacture specifications at this time also change filters in home.

附近 太阳浆果, 育空河, OK 73099
rodneys@www.imperialcheats.com

rodneys@www.imperialcheats.com

蓝盾降落服务. 更换了所有过滤器. 风机电机运行电容器检查良好, 热表面点火器检查正常, 清洗和检查火焰传感器, 压力开关检查良好, 诱导电机运行负载安培在MFG规格内, 轧辊开关检查合格, 高限位开关检查正常, 歧管压力为3.5在厕所, within mfg specs, air temperature rise is 59 degrees, within mfg specs. 房子里没有一氧化碳探测器. Highly recommend one be installed in each bedroom. 我做了一氧化碳检查. 结果——Oppm.

附近 《博士, 育空河, OK 73099
杰森B.

杰森B.

2021年11月12日杰森·B来到这里进行秋季调整. 与Thomas谈了系统性能. The system is having long run times to maintain 72 degrees in heating. Cycle system on at thermostat then disconnect power at furnace. Pull blower and coil door, inspect heat exchanger, capacitor and blower 电动机. 重新安装鼓风机拉并清洁火焰传感器. 测试所有压力开关,然后重新接通电源. 循环系统在加热. 检查HSI,燃烧器和所有安全装置. Check amp draws, inducer, gas manifold, temperature split, and CO Levels. 改变过滤器14 x30 & 14x14 发现气体压力为2.9调整到3.5 I.W.C. we are going to see if adjusting the gas pressure up resolves the long run times. If not please reach out and we can look at other options. 周末愉快!

附近 西北35圣, 育空河, OK 73099
克里斯·D.

克里斯·D.

11月11日来到这里进行冬季访问,检查了所有everything’产品的制造规格.

附近 西北87圣, 育空河, OK 73099
克里斯·D.

克里斯·D.

到11月5日回调发现在检查单位发现我已经离开火焰传感器关闭,这是它没有运行的原因

附近 Glascow博士, 育空河, OK 73099
rodneys@www.imperialcheats.com

rodneys@www.imperialcheats.com

10-31-21- no heat, found blower 电动机 shorted and burned up. 11-3-21-带风机马达和阀盖返回, removed old 电动机 and installed new 电动机 and cap, 清洗火焰传感器, 压力开关检查良好, 管汇压力好, 3.5在厕所. 系统运行正常.

附近 追逐Ln, 育空河, OK 73099
克里斯·D.

克里斯·D.

11月3日抵达,进行全面调试,检查气体压力,温度升高,感应电机和鼓风机电机的安培改变蓝色everything’,在制造规格内,客户改变自己的过滤器.

附近 Glascow博士, 育空河, OK 73099
克里斯·D.

克里斯·D.

客户在10月29日抵达进行炉子调试时表示,炉子从来没有工作过,他表示,除了系统中的一个关闭之外,所有的燃烧器都打开了. 这种情况的诊断是,最后一个燃烧器在办公室有堵塞,能够消除堵塞,在Hylo阶段测试,在低阶段有1.6 inches of water column and in high stage it was set to 3.5 inches of water column also removed cleaned and reinstall 火焰传感器 on cleaning it was running at 2.9直流毫伏系统上的温升在47°温升运行和高阶段制造规格在40和70之间,客户已经改变过滤器留下了一组额外的过滤器,客户系统运行在制造规格.

附近 卡迪夫Pl, 育空河, OK 73099
杰森B.

杰森B.

25OCT2021 杰森B Arrived at warranty call from recent install. 经检查的炉烟道. Shifted storm collar up applied silicone around flue. Shifted storm collar back down and applied silicone around ring. Penetration sealed and the system is ready for inspection.

附近 西南17圣, 育空河, OK 73099
杰森B.

杰森B.

杰森·B来到这里进行秋季调整. 和Jane谈了系统性能. Cycled system on at thermostat then disconnect power at furnace. Pull blower 电动机 and coil door inspect heat exchanger, capacitor and blower 电动机. 重新安装鼓风机拉并清洁火焰传感器. 测试所有压力开关,然后重新接通电源. 循环系统在加热. 调整气体压力至3.5 IWC. 检查HSI,燃烧器和所有安全装置. Check amp draws, inducer, gas manifold, temperature split, and CO Levels. 此时系统运行正常. 改变过滤器14 x24x1

附近 莱斯特博士, 育空河, OK 73099
艾萨克·J.

艾萨克·J.

Performed preventative maintenance tune up on furnace. System was installed in 2012 and is located in the attic. 顾客们只在这个房子里住了两年,他们想检查一下加热器,确保在它变冷之前一切正常. 我检查了管道系统, 风机组装, 电动机, 电器元件, 燃烧器, 火焰传感器, 点火器, 诱导电机及设备整体状况. Cleaned 火焰传感器 and blew dust off the 燃烧器 and components. Checked operation, wiring, amps, temperatures and adjusted gas pressure. System is heating properly within manufacture specifications at this time. 不管怎样我, 建议清洗管道系统,因为在返回系统中有大量的积液. Also, increasing the return sizes, due to them being inefficient for the 4 ton system. This is causing the system to strain over time and run longer do to the lack of air flow. I discussed the possibility of doing an air balancing

附近 西北1 St, 育空河, OK 73099
克里斯·D.

克里斯·D.

10月19日抵达秋季预演换热器火焰传感器检查气压火花点火注意到当我进入阁楼的东西可能是气体但不太确定通知客户提供关闭天然气客户不想做,说她会有人检查煤气管道. Customer change their own filters checked blower furnace is running within manufacture specifications at this time.

附近 西北84圣, 育空河, OK 73099
杰森B.

杰森B.

17OCT2021 杰森B Arrived to club member service call, spoke with John about what was happening. 他们的噩&beplay2网址恒温器最近一直嗡嗡作响. 在与OG交谈之后&关于这件事,有人建议他们与我们联系. When I inspected the thermostat I found no visible damage to the board, However there was a smell. 在所有模式下运行系统. 当我试图连接OG时&E网络我收到一个网络错误. This thermostat is defective and can no longer connect to the OG&E网络.

附近 艾琳大街, 育空河, OK 73099
约瑟夫·K.

约瑟夫·K.

I arrived for a new customer system replacement bid. 我和房主进行了交谈,我们讨论了现有系统的问题,以及他们希望通过今天的访问完成什么. 我们讨论过他们想要只更换蒸发器和鳕鱼我们想要在16和14个seer系统上得到不同的价格. 我们按照房主想要的方式建造了所有的投标,并讨论了warranty’s和拥有一个完整的系统更换或只更换半个系统的好处. 我会继续跟进homeowner on Friday about the system replacement.

附近 Apache门博士, 育空河, OK 73099
杰森B.

杰森B.

添加制冷剂拨号充电

附近 野蛮人, 育空河, OK 73099
艾萨克·J.

艾萨克·J.

Arrived on 3 October for a hot water tank leaking found that the high pressure relief valve was leaking water. 艾萨克·J - 我用真空把排水管里的水吸了出来. 潘并不需要被替换. I replaced the male pvc fitting, rubber gasket and ring. I made sure it was installed properly to keep water in the pan and drain properly through the emergency drain. I also redid part of the emergency drain and primary drain for the evaporator coil. Took the relief valve out and found it not seated properly. 我重新安装了它. 热水箱不再漏水. Reset hot water tank and made sure it was igniting.

附近 Bonnycastle博士, 育空河, OK 73099